Guide 115 · Transfer switch

Generator Power Inlet Box: Plug Types, Wiring and Installation

A generator power inlet box is a weatherproof socket on an outside wall, wired to a transfer switch inside. The generator plugs into it with one cord. The common 30-amp version, Reliance's PB30, takes an L14-30 plug and is wired with copper, AWG #10 to #8. Reliance says a qualified electrician has to install it.

Updated Drafted and checked with AIFact-checked by the HoldBackup editorial team How this guide was made

On this page
  1. What a power inlet box does
  2. Inlet types by plug and amp rating
  3. Check your generator's outlet first
  4. How an electrician installs it
  5. What else the electrician will check
  6. What comes in the Reliance kit, and where to mount it
  7. Plan the generator and its setup
  8. Sources

Affiliate disclosure: some store links on HoldBackup are affiliate links. If you buy through one, HoldBackup may earn a commission at no extra cost to you. As an Amazon Associate I earn from qualifying purchases. How HoldBackup makes money

The verdict

Match the inlet to your generator's outlet first: an L14-30R outlet pairs with a 30 A, 125/250 V inlet like the PB30. The Reliance 31410CRK kit this page links comes with a PB30 inlet and a 10-foot cord along with the 10-circuit switch, so you don't buy an inlet separately.

See the store link

What we check

What the store link is
A 10-circuit, 30-amp manual transfer-switch kit with a PB30 inlet box and a 10-foot L14-30 cord, as Reliance lists it.Maker-rated
Generator outlet
The kit's inlet and cord are L14-30, rated 30 A at 125/250 V. Check that your generator has an L14-30R outlet.Maker-rated
Transfer equipment
Reliance's inlet instructions require a transfer switch when the inlet powers a building.Published guidance
Generator placement
Outside and far from windows, doors and vents, per CPSC. The kit's cord is 10 feet long.Published guidance
Standby generator: louvered weatherproof cabinet on a concrete pad with clearance from the house wall, a lit status light, and a conduit run across the setback to a wall box

Drawing of backup power equipment.

Store link Transfer switch

Reliance Controls 31410CRK Pro/Tran 10-Circuit 30 Amp Generator Transfer Switch Kit,Gray

One listing to compare. Check its specs against the list above before you buy.

PriceAmazon sets it, and it changes. The button takes you to today's price.

Store linkPaid link

The unit named above, on Amazon.

Check price on Amazon

HoldBackup earns a commission if you buy through this link. Amazon sets the price.

Who shouldn't buy this

  • You plan to install it yourself. Reliance says a qualified electrician must install the inlet and the switch.
  • Your generator has no L14-30R outlet. The kit's inlet and cord won't plug into it as they come.
  • You only want a standalone inlet box. The store link is a kit with the switch, inlet and cord.

Generator safety: carbon monoxide and backfeed

Carbon monoxide: never run a generator indoors, in a garage, basement or crawlspace, or near windows, doors or vents. Using a generator indoors can kill you in minutes. Use battery-powered carbon monoxide alarms in the home. CPSC Safety Alert 5123

Backfeed: never plug a generator into a wall outlet or a dryer outlet. That is extremely dangerous: it can energize utility lines and injure line workers and people in the home. Use a transfer switch or interlock installed by a licensed electrician. CPSC Safety Alert 5123 (PDF)

What a power inlet box does

A power inlet box is a male socket in a weatherproof box on the outside of the house. The generator cord plugs into it, and wiring through the wall carries that power to a transfer switch or a generator-ready panel. Reliance describes its PB-series boxes as raintight, NEMA 3R, and usually installed outdoors where the generator is used.

The inlet only makes the connection. Reliance's PB30 instructions say that when it powers a building, it must be used with a transfer switch. The box is not for indoor use, and with an engine-driven generator Reliance says to locate away from doors and windows so carbon monoxide from the exhaust can't build up in enclosed areas.

Inlet types by plug and amp rating

Pick the inlet by the outlet you will use on the generator. The 125/250 V models carry 240 V as well as 120 V. The 125 V models match 120 V-only plugs. Reliance's catalog lists its metal PB-series inlets this way, and its plastic PBN series has the same models plus a PBN52 with a 14-50 plug:

  • PB15: 15 A at 125 V, 5-15 plug
  • PB20: 20 A at 125/250 V, L14-20 plug
  • PB30: 30 A at 125/250 V, L14-30 plug
  • PB31: 30 A at 125 V, L5-30 plug
  • PB50: 50 A at 125/250 V, CS6375 plug
  • PB51: 50 A at 125 V, CS6377 plug

Check your generator's outlet first

The PB30 and the cord in the Reliance kit use the L14-30, a four-wire locking connector rated 30 A at 125/250 V. Reliance's instructions say the generator end of the cord gets a plug that matches the generator's outlet, typically an L14-30P. Look for an L14-30R outlet on your generator's panel or spec sheet.

Some generators don't have one. Champion's 4000-watt dual fuel inverter, model 201050, lists a TT-30R RV outlet and a household duplex, both 120 V, and no L14-30R. The PB30 kit won't plug into that generator as it comes. Ask your electrician what your generator's outlets can safely feed before you buy an inlet or a kit.

The rating also caps what crosses the inlet. At 30 A and 250 V, that is 30 × 250 = 7,500 watts at most, and a 20 A inlet tops out at 20 × 250 = 5,000 watts (arithmetic). Your generator's running watts and the circuits on the switch decide what you can actually run.

How an electrician installs it

Reliance's PB30 instructions describe the job. The installer mounts the box outside using the three holes in the back of the cabinet, then runs copper wire through a knockout to the transfer switch, either directly or to a junction box beside it. Reliance's catalog lists four combination 1/2-inch and 3/4-inch knockouts, one on each side, the bottom and the back.

In conduit, Reliance calls for at least three color-coded wires, AWG #10 minimum and #8 maximum: white for neutral, and two other colors, usually black and red, for the 240 V line. Without conduit, a green ground wire is added. Wires are stripped 5/8 inch, and the inlet's terminal screws are tightened to 20 inch-pounds.

The kit's switch, the 31410C (now the 310C), is an indoor model with no inlet of its own, so it is hard-wired to the remote inlet. Reliance's switch manual has the switch's black and red leads go to the inlet's X and Y terminals, white to the neutral W terminal, and green to the G ground terminal. Reliance favors a remote outdoor connection because it makes running the generator indoors, which it calls extremely dangerous, less likely.

Bring this to the electrician before any parts are ordered:

  • Your generator's outlet type and rated running watts
  • The circuits you want on generator power, from your panel's labels
  • Where the generator will sit during an outage
  • Whether your area needs a permit and inspection

What else the electrician will check

Reliance's switch manual flags two things for the installer. A circuit on an AFCI or GFCI breaker loses that protection while its switch is on GEN, unless matching breakers are installed in the transfer switch. A circuit that shares a neutral with another, called a multi-wire branch circuit, needs both circuits on the switch, on opposite legs, with a handle tie so they transfer together. Reliance warns that getting this wrong can overload the neutral wire.

On the 10-circuit switch, Reliance's catalog lists circuits A and B at 30 A maximum and every other circuit at 20 A, and the manual says only A and B can be used for 30-amp circuits. The C models have analog wattmeters that show the load in watts on each side of the generator.

Both the PB30 instructions and the switch manual say installation must be done by a qualified electrician in compliance with all applicable electrical codes.

What comes in the Reliance kit, and where to mount it

The store link on this page is the Reliance Controls 31410CRK. Reliance's catalog lists that as the older model number of its 310CRK kit, which comes with the 310C ten-circuit transfer switch, a PB30 outdoor power inlet box and a PC3010M 10-foot outdoor power cord. The cord has L14-30 ends, 10-gauge 10/3 with ground SJTW conductors and a lighted connector. If you buy the kit, you don't need a separate inlet.

The kit's cord is 10 feet, so the generator can sit no more than 10 feet from the inlet. CPSC says to run a generator outside and far from windows, doors and vents, and to use cords long enough to allow that. Mount the inlet on a wall section with none of those nearby, or plan on a longer cord. Reliance's catalog lists a 20-foot cord, the PC3020, in its other kits.

CPSC says to check the full length of the cord for cuts or tears and to protect it from being pinched or crushed where it passes through a window or doorway.

Plan the generator and its setup

Sources

Recorded AI check: Nov 9, 2026. The sources below may include later additions. AI checks compare factual numbers and checkable claims with web sources; they do not verify every statement.

Best inverter generator for a home outage compares units from the makers' numbers. Every guide in this class is in Portable generators.

How this guide was made

  1. Drafted and checked with AI. An AI model wrote the draft from the guide's topic. A second AI pass looked for factual numbers to check against web sources. This does not verify every statement. A draft that fails the check is held for review.
  2. Fact-checked by the HoldBackup editorial team. On , a person on the HoldBackup editorial team reviewed this guide against its sources. That is a review of the writing, not a test of any unit.
  3. General guidance only. No prices, rankings, or test results, because we have none to back them. Check any number against the maker's own spec sheet.
  4. No lab tests, and we say so. HoldBackup has not run any unit named here.
  5. The store link is not a pick for this guide. It goes to a unit in this product class that this guide does not review. Check it against the list above before you buy.
  6. Labelled store links. A store button goes straight to Amazon with HoldBackup's affiliate tag. HoldBackup counts the click. A live button carries a "paid link" label, and the disclosure sits above the first one on every guide.

Recent updates

  1. Fact-checked the rewrite, checks box and skip list against the guide's sources.
  2. Rewrote around Reliance's inlet, switch and catalog specs, and noted that the kit includes a PB30 inlet and a 10-foot cord.
  3. Fact-checked the checks box, skip list and log against the guide's sources.
  4. Added the checks box, the who-shouldn't-buy list and this log.
  5. Fact-checked against the guide's listed sources.
  6. Corrected the guidance on connectors, transfer equipment and what the store link leads to.
  7. First published.

Questions

What plug does a 30 amp generator inlet box use?

Reliance's PB30 uses an L14-30, rated 30 A at 125/250 V. The cord has an L14-30C connector on the inlet end and, on the generator end, a plug that matches the generator's outlet, typically an L14-30P.

What size wire runs from the inlet box to the transfer switch?

Reliance's PB30 instructions call for copper wire, AWG #10 minimum and #8 maximum: white for neutral and two other colors, usually black and red, for the 240 V line, plus a green ground if there's no conduit. Your electrician sizes the final run under local code.

Does the Reliance 31410CRK come with an inlet box?

Yes. Reliance's catalog lists the 31410CRK as the older model number of its 310CRK kit, which includes the 310C ten-circuit transfer switch, a PB30 power inlet box and a PC3010M 10-foot power cord with L14-30 ends.

Can I use a generator inlet box without a transfer switch?

Not to power a house. Reliance's PB30 instructions say that when the inlet powers a building, it must be used with a transfer switch, installed by a qualified electrician.

Where does the price button go?

Straight to Amazon. Amazon sets the price and availability, and both can change.

More guides

  1. Transfer switch

    Transfer switch switchover steps: to generator power and back to the grid

    The safe order for moving circuits from the grid to a generator through a manual transfer switch, and back again when utility power returns.

  2. Transfer switch

    Load Shedding Modules for an Automatic Transfer Switch: Do You Need Them?

    What load shedding modules do on an automatic transfer switch, when you need them, when you can skip them, and what to check before buying.

  3. Transfer switch

    Transfer Switch Permits: Do You Need One and an Electrician?

    Installing a generator transfer switch usually means a permit and a licensed electrician. Here is what to check before you buy a switch kit.

  4. Transfer switch

    How to read transfer switch wattmeters without overloading a generator

    Learn to read the wattmeters on a manual transfer switch, balance both legs, and keep your generator under its running rating during an outage.

Browse all guides