How long will a UPS run your devices?
Tick what has to stay on. This adds up the watts and reads each maker's runtime chart at that load. It's arithmetic, not a test.
This page has no store links. The pages it links to carry disclosed affiliate links.

How it's worked out
load W = the watts of everything ticked, added upcarries it = load ≤ the UPS's watt rating × the share aboveruntime = the maker's figure at the next heavier load it publishes
The result above starts with a modem and Wi-Fi router and a 4-bay NAS: 58 W. Each maker publishes runtime at a set of loads. The page finds the first of those at or above yours and shows that figure.
Why it says "at least"
A UPS runs longer on a lighter load, so the maker's figure for the next heavier load is the shortest runtime its chart supports for yours. We don't estimate between two published figures, because the curve between them isn't a straight line. Under each answer you'll see the figures on either side, so you can judge for yourself.
"At least" compares your load with the maker's chart. It isn't a guarantee. Both makers say their figures are estimates for a new, fully charged battery in normal conditions.
Why there's no battery formula
Some calculators multiply battery volts by amp-hours and divide by watts. Runtime doesn't scale in a straight line with load, so that sum drifts from what the maker measured. How to Estimate Battery Backup (UPS) Runtime for Your Devices walks through reading one.
Watts and VA are separate limits
A UPS has a watt rating and a VA rating, and the load has to stay under both. This page checks watts from the figures above. It checks VA only if you enter a total from your device labels. UPS VA vs Watts: How to Read a Battery Backup (UPS) Rating explains the difference.
What it leaves out
- Battery age. Every figure here is for a new battery. An older one runs for less.
- Other models. Only units whose maker's chart we've read are listed. For any other UPS, read its own chart at your load.
- Your own numbers. A plug-in watt meter beats every preset here.
If a medical device has to stay on, ask your medical provider and the device's maker what they recommend. This page isn't medical advice.
Sources
- APC BE600M1, maker's runtime chart, read Nov 9, 2026
- CyberPower EC650LCD, maker's runtime chart, read Nov 9, 2026
- APC BR1500MS2, maker's runtime chart, read Nov 9, 2026
- CyberPower CP1500PFCLCD, maker's runtime chart, read Nov 9, 2026
- Schneider Electric, Things to consider in sizing a UPS and load
- Watts for Modem and Wi-Fi router; 4-bay NAS, in use; Laptop on a 40 W adapter: the runtime table's sources.
For hours instead of minutes, use the power station size calculator or the generator size calculator. To write a UPS plan down, use the UPS sizing worksheet.